JASO D611 STANDARD PDF

September 6, 2019 posted by

Automotive Cables to ISO, SAEJ, JASO D Automotive Cables. APPLICATIONS OVERVIEW. Standard wall automotive cables are ideal for use in. AVSS Automotive Wire JASO D Construction (No./mm), calculated area ( mm2), Outer Diameter (mm), Standard (mm), Min. (mm), Standard (mm), Max. AVSS Japanese Standard Automotive Cable Conductor:Cu-ETP1 bare according to JIS Insulation:PVC Standard Compliance:JASO D

Author: Makasa Akinosar
Country: Bahrain
Language: English (Spanish)
Genre: Music
Published (Last): 22 February 2008
Pages: 76
PDF File Size: 14.44 Mb
ePub File Size: 17.65 Mb
ISBN: 761-9-58857-311-7
Downloads: 42630
Price: Free* [*Free Regsitration Required]
Uploader: Faell

AVSS – Japanese Standard Automotive Cable

Minimum values shall be as specified in Table 8. The meanings of the symbols for cable types are as follows. This is caused by the difference in the concept of temperature resistance as shown in Note 2 of Table 1, and it was determined to describe both values separately depending on the cable types. Compressed conductor ultra thin wall halogen-free insulated low-voltage cables for automobiles Jaao At the time of establishment, thin wall low-voltage cables generally called AVS that have thinner insulation covering and thin wires with a conductor sectional area of 5 mm2 or less were widely used to reduce the weight and size of wire harnesses for automobiles.

Details of specified items in specified elements 5. Cable types, symbols, and insulation materials The cable types, symbols, and insulation materials are as shown in Table 1. Therefore, all materials are described in Table 1. In addition, this standard does not specify indication of the rated voltage on the cable itself or packaging.

AVSS JASO D611

This revision increased the number of types significantly, but the standard now covers all types in consideration of the current production and distribution status. Product designation Product designation is based on the applicable standard name, type, nominal size, and colour, or by means of symbol, nominal size, and colour code.

  BOUND AND DETERMINED DAVITT PDF

The heat resistance B test shall be conducted in accordance with the method specified in 5. Therefore, the horizontal burning test in the JASO standard was adopted. In addition, the cables conforming to ISO in this iaso are as follows: The insulation ator shall not be fractured in the voltage resistance test in 6. Performance Cable performance shall be as specified in Tables 2 to 7. Test method detail item 6.

Outline and background of revision 1. This test is applicable to the nominal sizes of 5 or less. Cross-linked vinyl insulated heat resistant earth bond low-voltage cables for automobiles AEX: Normative reference The following standards, when referred to in this standard, constitute a part of the specifications of this standard.

The winding test shall be conducted in accordance with the method specified in 5. All matters such as the testing method and testing jig shall be handled as common knowledge. For the insulation materials, polyvinyl chloride mixture, halogen-free mixture, cross-linked PVC mixture, heat resistant PVC mixture, and cross-linked polyethylene mixture are used depending on the heat resistance standzrd, and have a different temperature rating.

Therefore, no wire diameter is specified in the construction table and only “circular compression” is described.

AVS pvc insulation automobile wire JASO D611 Japan standard

Therefore, cables of different classes cannot be integrated simply as a single type, and are used separately. Therefore, in this revision, standards for rated voltage of 25 VAC and 60 VDC are provided mainly for cables with thin insulation covering specified by JASO according to the international standard.

The insulation shall not be fractured in the d161 resistance test in 6. The nominal size includes the “f” type. In addition, the necessity and method of voltage indication must be discussed to establish its future direction. The identification mark stabdard be readable stadard the specified test. For other fuels, the test shall be performed upon an agreement between the parties involved in delivery. The impact test shall be conducted in accordance with the method specified in 5.

  HYPOTHERM POWERMAX 1250 PDF

Another idea was proposed that the rated voltage should be indicated on the cable packaging for manufacturers that use the cables for electric devices in EVs and HEVs, but it was also not adopted because of the cost and time required jso such indication. The meanings of the heat resistant are as follows. For this reason, the current details are applied unchanged.

After study by the Electrical and Electronic Equipment Subcommittee and the Standardization Board, the revision was approved and determined at the standardization meeting in March In addition, the performance with different nominal sizes shall be as specified in Tables 8 to The tests requiring different performance depending on the nominal size are described in Table 8 to Matters of concern This revision tried to adopt all test items specified in ISObut six items could not be included.

Inthe standard was revised to include these cables. The heat resistance A test shall be conducted in accordance with the method specified in stanvard. However, the use of “f” is neither standsrd nor clear.

China UL, Jaso D Standards AVS Type Automotive Wire Photos & Pictures –

The scrape abrasion test shall be conducted in accordance with the method specified in 5. The burning cable shall self extinguish within 30 seconds after exposure to naked flame.

The construction shall conform to the applicable standard in Tables 11 to 25 when the test is conducted according to Item 6. Marking The following items shall be marked on the packaged products using indelible ink.