The ISO Central Secretariat accepts no liability in this area. International Standard ISO was prepared by the European Committee for. Buy KS B ISO Mechanical vibration — Measurement and evaluation of human exposure to hand-transmitted vibration — Part 2: Practical guidance. ISO MECHANICAL VIBRATION – MEASUREMENT AND EVALUATION OF HUMAN EXPOSURE TO HAND-TRANSMITTED VIBRATION – PART 2.

Author: Voodoorg Aragore
Country: Australia
Language: English (Spanish)
Genre: Automotive
Published (Last): 23 April 2005
Pages: 145
PDF File Size: 8.69 Mb
ePub File Size: 2.66 Mb
ISBN: 894-9-95722-842-2
Downloads: 34134
Price: Free* [*Free Regsitration Required]
Uploader: Ararr

The centre of gravity of the accelerometers shall not be more than 20 mm away from the nearest hand. In practice, the measurement location usually has to be to one side of the hand. Attention is particularly drawn to the following: The reported result shall be the arithmetic mean of the measurements, the standard deviation should also be recorded.

Some of the ISO standards related to Hand-arm vibration are listed below: The lighter the accelerometer s the smaller the error introduced see 6. Click to learn more. The vibration exposure may vary greatly from one operation to another, either due to the use of different power tools or machines or different modes of operation of one power tool or machine.

In these cases short-term measurements can only be made during each phase of the work operation. The range of vibration total value ahv was as follows: Frequency isso will also provide information on any dominant frequencies, and harmonics, which may help to identify effective vibration control measures. For straight control-handle power tools, the transducer shall be oso so as to measure the acceleration on the power tool surface in a tangential direction relative to the.

An Introduction to Hand/Arm Vibration – National Instruments

Examples of this type of operation are levelling a large area using a vibrating plate tamper, floor polishing and ride-on lawn mowers. In most cases this approach will be adequate.

In this case the transducer shall be placed as close as possible to the hand, between the thumb and the index finger, or as close as possible to the halfway location. However, much of this energy is at frequencies well outside the frequency range used in this part of ISO These systems are more costly isso complex to operate than the single-unit systems. International Standard Title ISO all parts Hand-held portable power tools — Measurement of vibrations at the handle For the purpose of deciding whether a particular requirement of this standard is complied with, the final value, observed or calculated, expressing the result of a test or analysis, shall be rounded off in accordance with IS 2: In this case measurements may be made during simulated work operations which artificially arrange longer uninterrupted exposures with work conditions as near to normal as possible.

  ABRIKOSOV GORKOV DZYALOSHINSKII PDF

The vibration exposure pattern is similar to that shown in Figure E. ISOHuman response to vibration – Measuring instrumentation. Therefore, the use of mechanical filters to prevent DC-shift is only necessary when using piezoelectric accelerometers.

The first of these will be a measurement to determine how long 549-2 operator is exposed to vibration, and from what source, during a specified period.

Generally, resilient materials on power tool handles are not intended to provide vibration reduction but to provide a good grip surface. Standards are also reviewed periodically; a standard along with amendments is reaffirmed when such review indicates that no changes are needed; if the review indicates that changes are needed, it is taken up for revision. Measurement of occupational vibration immissions – Part 3: Mechanical filters are available from some transducer manufacturers, or can be constructed using suitable resilient materials.

It is important that digital methods, such as digital filtering and Fast Fourier Transform FFT analysis, are properly capable of providing accurate analysis over the full frequency range covered by the one-third-octave bands from 6,3 Hz to Hz.

A method shall be chosen which gives an adequate fixing to the oso surface, does not interfere with the operation of the power tool and does not itself affect the vibration charadteristics of the vibrating surface. Often a typical daily vibration exposure time will be based on – a measurement of the actual exposure time during a period of normal use e.

We use cookies to make our website easier to use and to better understand your needs. You may find similar items within these categories by selecting from the 55349-2 below:.

  C RANGARAJAN COMMITTEE REPORT ON SUGAR PDF

The transducer s on the handles if any shall be positioned jso along their length and, preferably, on the underside. However, the DC-shift distortion will affect the entire vibration spectrum. These systems are designed primarily to evaluate the vibration exposure at the is they are generally sufficient for most situations covered by this part of ISO The goal for tool manufacturers should be to reduce vibrations through better design of tools.

Test calibration and assessment of the vibration meter – Primary test, verification, intermediate test, check in situ. The vibration can cause the blood pressure in the hands to drop, resulting in limited blood flow to the fingers.

For difficult surfaces, individually moulded adaptors may be suitable. They should not have any structural resonances which would affect the measured vibration.

It is important, prior to measurements, to observe how a power tool or hand-held workpiece is held, to identify the best location and orientation of the accelerometers. The normal position of the transducer shall be halfway 5439-2 the length of the handle.

Practical guidance for measurement at the workplace Status: The results of these verification checks shall be recorded.

Inthe EU Vibration Directive was implemented, putting increased emphasis on the testing and effects 534-2 vibrations resulting from machinery.

Worldwide Standards We can source any standard from anywhere in the world. For evaluation jso vibration exposure, the location of the accelerometers shall be based on where the hand actually holds the power tool, rather than where the power tool is held during a type test.

Work records show that an average of castings are worked on per day.

BS EN ISO 5349-2:2001+A1:2015

Where such evaluations are carried out, evaluation of actual daily vibration exposure should also be made and reported. To obtain a good picture of the average daily vibration exposure it is necessary to identify all a sources of vibration exposure i. Guidelines for Tool Manufacturers The goal for tool manufacturers should be to reduce vibrations through better design of tools.